Xiamen Xiang 'an Hospital

PROJECT REQUIREMENT

All purification air conditioning units (circulation units and fresh air units) are medical health air conditioning units. The operation department, obstetrics, medical technology building ICU single room and hall purification area of the inpatient building centralized supply of fresh air, fresh air adopts double cold source treatment: water coil fluorine coil. After deep dehumidification, fresh air enters the circulating unit to complete the whole air treatment process.


Located in Xiamen City, Fujian Province, Xiang 'an Hospital is the only hospital directly affiliated to Xiamen University. It has been built into a comprehensive clinical research hospital integrating medical treatment, teaching, scientific research and prevention in accordance with the standards of third-class first-class hospitals. Total area of 360 acres. The building group includes outpatient building, emergency and critical care building, medical technology building, science and education complex building and two inpatient buildings.

Air conditioning scheme:
In order to meet the demand of air volume, the 15600 and 14300 air volume units in the purification area of the operation department were equipped with 12 pieces of deep dehumidifier respectively. The 12,000 and 10,000 air volume units in the maternity purification area, ICU single room in the medical technology building and the purification area in the hall are equipped with 25 and 15 deep dehumidifiers respectively.

Selection analysis:
The sequence of functional segments of the unit is: mixing section, coarse filter section, fan section, flow sharing section, medium filter section, maintenance section, high efficiency section, surface cooling section, maintenance section, deep dehumidification section, air outlet section. The fresh air unit is mainly to achieve fresh air filtration and main cooling and dehumidification functions, and the water coil, as a first-level surface cooling, is the main part of cooling and dehumidification. As a guarantee, the deep dehumidification section is placed after the water coil, when the dehumidification capacity of the water coil is insufficient, when the dehumidification requirements are higher, such as the plum rain season, back to the south, and continuous rainy days, it can be quickly opened to help dehumidification.

Project summary:
Project location: Xiamen, Fujian
Industry: Hospital
Adopted model: EKDM combined air conditioning unit

EKDM deep dehumidification unit